240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (2024)

240W LED street light power supply

240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (5)240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (6)

  • Introduction

Features:

■Universal input voltage design(90Vac~305Vac)
■Output voltage and current parameters support the client settings
■High power factor, low harmonics
■High efficiency design (up to 90%)
■Protection Design: Short-circuit, over-voltage, over-temperature
■suitable for LED Lighting
■IP65/IP67 grade,could be install in indoor and outdoor
■3years warranty

Dimming optional:

3 in1 online dimming(Equipped with 3-in-1 dimming function, through the product dimming cable access resistance / PWM signal / (0 ~ 10Vdc) level of any signal,to achieve online dimming function)Programming (output current control settings, up to 2 dimming section)

Structure

L*W*H:L208*68W*H39mm

240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (7)

Specification

ModeldZF-HLB-240-36ZF-HLB-240-42ZF-HLB-240-48ZF-HLB-240-54Customized
OutputNo-load voltage(MAX)37VDC43VDC49VDC55VDCCustomized
Output current(Typ)6.6A5.7A5A4.5ACustomized
Output Power(MAX)243W243W243W243W243W
纹波与噪声Remarks2300mV300mV300mV300mV300mV
Output voltage range25-36VDC25-42VDC25-48VDC38-54VDCCustomized
Conversion efficiency(Typ)≥86%≥86%≥87%≥88%≥88%
Current error(MAX)±2%±2%±2%±2%±2%
Linear adjustment rate±2%±2%±2%±2%±2%
Load Regulation±2%±2%±2%±2%±2%
Start Time Remarks3≤800ms,≤1500ms(Full load)230VAC/115AC
Hold time(Typ)10msFull load 230VAC/115VAC
InputVoltage range100-300VAC Or 130-430VDC(When the AC input voltage is higher than 277VAC, the APFC is turned off and the power supply works without PFC correction.)
Frequency Range47-63HZ
Power factor(Typ)PF≥0.98230VACFull load
Total harmonic distortion(Typ)<15%(Loaded lamps as standard)
Alternating current(Typ)<0.8A/115VAC,<0.45A/230VAC, <0.35A/277VAC
Inrush current(Typ)Cold start<80A /230VAC
Leakage current<0.75MA/300VAC
ProtectionOvercurrent100%
Short circuitProtection mode: snoring, the short circuit can be restored after removal
Overload protectionMaximum operating voltage limit。
Over temperature protectionProduct internal temperature monitoring point>Start after 90 °C, reduce the output current as the temperature rises (the dimming product does not have this function)
EnvironmentOperating temperature-40---+60℃
Working humidity20-95%RH,No condensation
Storage temperature, humidity-40-+80℃,20-95%RH
Maximum temperature rise+30℃ Windless open environment, maximum temperature point of the enclosure
Vibration resistant10-500HZ,5G 12Minute/cycle,X, Y, Z axis 72 minutes each
Safety and electromagnetic compatibilitySafety regulations Remarks4EN 61347-1:2008+A1:2011+A2:2013 , EN 61347-2-13:2006 , EN 62493:2010
Withstand voltageI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1KVAC
Insulation resistanceI/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/70%RH
Electromagnetic compatibility emissionEN55015 , EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009
Electromagnetic compatibility immunityEN55024-A , EN61000-3-3:2013
Lightning surgeCommon modeL/N-FG,±6KV
Differential modeL-N,±5KV
WireRubber lineInput line3*0.75²
Rubber lineOutput line2*0.75²
ShellAll aluminum ShellSilicone filling and filling
OtherMTBF≥150Khrs;MIL-HDBK-217F(25℃)
Body sizeL228*W67*H42mm
Product Weight
Package carton sizeL188*W75*H43
Remarks1.Unless otherwise stated, all specifications are measured at an input temperature of 230VAC. 25°C ambient temperature.
2.Ripple and noise measurement method: use a 0.52mm twisted pair cable, and the terminal should be connected with 0.1uf and 47uf capacitors in parallel and measure at 20MHz bandwidth.
3.The startup time is measured under the cold start, and frequent switching machines may change the startup time.
4.Safety designTUVEN61347-1,EN61347-2-13,IEC/EN60968-1.2004+A1:2006
5.The power supply is considered to be a component used in conjunction with the terminal equipment. Because the EMC is affected by the complete unit, the terminal equipment manufacturer needs to confirm the EMC of the entire unit.

Block diagram

240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (8)

Dimming function (optional)

※ The output current can be adjusted by potentiometer with DIM+, DIM-connected 1~10Vdc, 10V PWM signal, and maximum resistance of 100K.

※ When using the potentiometer to control the dimming, only one product can be controlled. If you need to control multiple products, you need to change the maximum value of the potentiometer. The resistance change calculation formula is: 100K/parallel control product = demand resistance The use of potentiometer to control multiple products is also affected by other conditions, and the actual experience is poor, so it is not recommended to use potentiometer to control multiple products.)

※ When controlling 10 products with 1~10Vdc, 10V PWM signal, ensure that the controller output current is ≥3mA

※ After the product is powered on, the DIM+ output line cannot be short-circuited with the LED+ output line to prevent the high voltage of the LED+ output from damaging the constant current control system inside the product.

※ Adjust the reference resistance of the output current (typical)

Resistance Value10KΩ20KΩ30KΩ40KΩ50KΩ60KΩ70KΩ80KΩ90KΩ100KΩOPEN
Rated current percentage10%20%30%40%50%60%70%80%90%100%95%-108%

※1-10V Dimming Function Adjusts Output Current (Typical)

Voltage adjustment1V2V3V4V5V6V7V8V9V10VOPEN
Rated current percentage10%20%30%40%50%60%70%80%90%100%95%-108%

※10V PWM Signal Adjust Output Current Value (Typical) Frequency Range: 100Hz-3KHz

Duty Ration10%20%30%40%50%60%70%80%90%100%OPEN
Rated current percentage10%20%30%40%50%60%70%80%90%100%95%-108%

Dimming connection block diagram of lighting device using controller to turn on/off

240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (9)

2. Dimming method 2: timing dimming

Timer dimming internally uses a microcontroller as a timer. A dimming ratio of 5% to 100% can be achieved.
This dimming method uses the power-on time as 0 o'clock. When the power supply starts the timer, it will restart at 0:00:00:00. Once the power is turned off or the power-on time is lost, the time will start again.
The minimum current changes by 1%. The maximum current changes by 95%. The minimum time set value is 1 second, and the maximum time setting value is infinite.For example, the output power of the customer is reduced to 70% after 3 hours of start-up, 50% after 5 hours, 35% after 6.5 hours, and then maintained. This can be achieved by this function.
Note: The start time of the dimming and the percentage of the dimming output current are set by the customer and cannot be changed once shipped.This control mode cannot turn off the power.
There are two ways of current regulation, one is real-time, and the other is gradual, such as reducing the weight to 100% and reducing it to 50%. In real time, it only takes 1 second to reduce the current by 100% to 50%. The gradual change is a gradual decrease at a rate of 1% per second. The reduction from 100% to 50% takes 50 seconds to complete. . Customers can choose a suitable change in a more practical environment.

Declaration

1.the picture is for reference only, products in kind prevail.
2.Due to errors in the test equipment, the conversion efficiency is only for reference.
3.power can not be soaked in water for a long time.

Product Usage Notes

1. When the device is powered, please pay attention to the correct installation of the input and output terminals.
2. When the power supply is turned on for the first time, if a light flash occurs, check the DC output terminal; if it is confirmed that the load voltage of the DC output terminal is lower than the minimum operating voltage, when the load voltage is lower than the minimum operating voltage, the power supply is not in operation. In the normal work area, various abnormal conditions will occur.
3. When the power is turned on for the first time, if the load power is low, check the DC output voltage and confirm whether the DC output voltage is lower than the maximum operating voltage. If the load voltage is higher than or equal to the maximum operating voltage, When the power supply enters the constant voltage operation mode, the power supply loses the constant current function and changes to the load impedance constant current. After encountering this situation, it is necessary to replace the power supply with higher operating voltage to properly match the lamps.

Warranty instructions

1.the warranty date start date is the product date of manufacture
2.The product damage caused by using the environment beyond the nominal range of the specification is not covered by the warranty.
3.Product damage caused by incorrect installation and use is not covered by the warranty.
4. Product failure caused by long-term immersion in water is not covered by the warranty.
5.Users will not warranty after disassembling the product

Prev:No

Next: 200W LED street light power supply

240W LED street light power supply-LED street Lighting-Shenzhen Zhongfu optoelectronics Technology Co., Ltd. (2024)
Top Articles
Latest Posts
Article information

Author: Rev. Leonie Wyman

Last Updated:

Views: 6269

Rating: 4.9 / 5 (79 voted)

Reviews: 86% of readers found this page helpful

Author information

Name: Rev. Leonie Wyman

Birthday: 1993-07-01

Address: Suite 763 6272 Lang Bypass, New Xochitlport, VT 72704-3308

Phone: +22014484519944

Job: Banking Officer

Hobby: Sailing, Gaming, Basketball, Calligraphy, Mycology, Astronomy, Juggling

Introduction: My name is Rev. Leonie Wyman, I am a colorful, tasty, splendid, fair, witty, gorgeous, splendid person who loves writing and wants to share my knowledge and understanding with you.